8 C45 User Guide Version 1.0
Operation
Switching on
At ‘switch-on’ the protection circuit will initially activate whilst the circuits stabilise. Assuming no faults
are detected after a few seconds, only the ‘POWER’ LED (and ‘SIGNAL’ indicators if signal is applied)
will illuminate.
Panel controls and indicators
Level controls
These are analogue controls allowing precise level settings. Note that in BRIDGED’ mode only
‘channel A’ control is active.
Signal Indicators (3 Green LEDs)
These are active from a minimum output level of approximately 10 Watts and are only an indication of
signal level.
-3dB Indicators (yellow LED)
These are active when the signal is 3dB below the limiting level.
Limiters (Red LED)
The C-Series amplifiers incorporate signal limiters, which are preset to prevent clipping with high
levels of drive. The amber LEDs on the front panel illuminate to indicate operation of the limiters.
PRC Indicators (green LED)
These indicate when the PRC circuit for that specific channel has been selected with the rear panel
switches.
Temperature Control
The cooling fans respond to temperature sensors within the unit to maintain a safe operating
temperature. In the event of excessive temperature, the protection circuit will operate, disabling the
output. The red ‘AUDIO-PROTECT’ (A/P) LED will indicate this condition. (See fault indicator.)
There are 4 fans connected permanently with variable speed and a jumper link to enable them from
cold.
Normal dynamic signals will not cause the amplifier to overheat unless the ventilation is
inadequate. (See installation section and maintenance section.)
Fault Indicator (Audio Protection red LED)
If the outputs are shorted or if DC is present, the protection circuit will disengage the outputs and the
A/P LED will illuminate. The amplifier will continue to be monitored and depending on the type of
fault, will either reset after the fault has cleared or require manual resetting by switching off at the
mains switch and then on again after a few seconds. (See also temperature control above.)
Temperature related faults will reset once the unit has cooled sufficiently.
Output short circuits will require manual reset after clearing the fault.
Bridged LED (green)
This indicates the position of the switch on the rear panel and is illuminated when bridged mode is
selected with the switch pressed in.